Case Study: Bath Spa University Air Conditioning Inspections by Syntegra

You are here: 

Syntegra Consulting has successfully undertaken the Air Conditioning Inspection of Bath University campus buildings.  Syntegra undertook the ACI inspection for a number of buildings around the campus that were provided with Air Conditioning. The inspected buildings include the Library, Student Union and Auditorium & Exhibition centre.

The undertaking of an ACI (Air Conditioning Inspection) is a legal requirement according to article 9 of the Energy Performance Building Directive in England and Wales (EPBD). Air Conditioning Inspections are mandatory for all buildings with installed systems with rated cooling output greater than 12kW. The air conditioning inspection consisted of site inspections and the production of the Air Conditioning Inspection reports, which presents the site inspections findings and the recommendations for improving the system’s energy efficiency in order to save energy and reduce carbon emissions.

The Bath Spa University buildings inspected lie under the packaged cooling and centralized cooling systems assessment since they are air conditioned by a number of VRV systems, single DX split systems and centralized Air Handling Unit (AHU) systems.

Syntegra consulting has managed to identify areas of improving the energy efficiency further of the building’s air conditioning system. Recommendations were made in upgrading AC equipment and control methodology. In addition, Syntegra investigated in improving the AC system’s efficiency and buildings overall energy performance further, by recommending the use of LED lighting. LED lighting is the most energy efficient lighting technology compared to conventional technologies. Furthermore, LED lighting generates minimum heat, which helps reducing a building’s cooling load from lighting. Therefore, LEDs not only reduce the lighting electricity cost, but also the AC (air conditioning) cost of electricity due to reduced heat gains (cooling load). In addition, Syntegra managed to present solutions involving energy/heat recovery systems.

For more information on Air Conditioning Inspections and FREE LED Lighting Feasibility Studies, please contact Syntegra Consulting on T: 08450 091625 and Email: mail@syntegra-epc.co.uk

What are the latest posts?

Frequently Asked Questions

1 What is a TM44 Air Conditioning Inspection and why is it required for institutions like Bath Spa University?

TM44 Air Conditioning Inspections are a statutory requirement for air conditioning systems with an effective rated output of over 12kW. These inspections ensure energy efficiency, identify potential improvements, and help comply with the Energy Performance of Buildings (Certificates and Inspections) (England and Wales) Regulations 2012.

2 What does Syntegra Group's TM44 inspection service involve for large university campuses?

While specific details of the Bath Spa University case study are not provided in the content, Syntegra Group offers TM44 Air Conditioning Inspection (ACI) services. These typically involve a thorough assessment of the AC system's energy efficiency, operational performance, and recommendations for optimization.

3 How can these inspections contribute to building compliance and maintenance for a university?

Regular TM44 inspections help universities maintain compliance with energy efficiency regulations, avoid potential penalties, and identify maintenance needs proactively. This contributes to better operational efficiency, reduced energy consumption, and a more comfortable environment for students and staff.

4 What other related environmental or engineering consulting services does Syntegra Group offer that might benefit a university?

Syntegra Group offers a range of relevant services, including Energy Strategy Reports, Overheating Assessments, BREEAM Assessment, Whole Life Cycle Carbon Assessment, and Indoor Air Quality Assessment. These can support a university's broader sustainability goals and building performance management.