Syntegra Consulting appointed energy consultants to undertake a site survey and building regulations compliance check report for Part L compliance for a  major property refurbishment and extension in Sonning Common, Reading. The following recommendations were as follows:

1    Glazing U-value to install as 1.6w/m2k

2    Roof insulated 300mm insulation

3    210 litre MEGAFLOW HE cylinder installed

4    Time, temperature zone control – heating installed

5    Cladding wall area insulated 100mm Celotex

6    Extension advised to be limited to 20.5m2

7    Lower part of extension to be cavity filled brick 600mm high with U = 0.3w/m2k