Odour Assessment

Odour can be an important consideration when assessing a proposed development, industrial process or environmental permit. It can also become a significant issue where sensitive uses such as residential developments are located close to an existing odour source.

Our odour consultants provide assessments for planning applications, environmental permitting and investigations into existing odour nuisance.

We assess the potential for odour impacts by considering the source, pathway and receptor, together with the characteristics, frequency and likely extent of the odour.

Odour Assessment for Planning Applications

An odour assessment may be required where a proposed development could generate odour or where a sensitive development is proposed close to an existing odorous activity.

Potential sources can include food and drink manufacturing, commercial kitchens, restaurants, agriculture, intensive livestock operations, waste facilities, composting, anaerobic digestion and sewage treatment works.

Our assessment considers the nature of the source and the potential impact on nearby sensitive receptors.

Odour Surveys and Monitoring

Where appropriate, we can undertake qualitative and quantitative odour investigations.

Qualitative assessments can consider the intensity, frequency, duration and character of odours using structured field assessment techniques.

Quantitative assessment may include field olfactometry or laboratory-based olfactometry and compound analysis, depending on the source and requirements of the project.

Odour Dispersion Modelling

Where emissions data is available, dispersion modelling can be used to assess how odour may travel from a source and the potential impact on surrounding receptors.

Modelling can consider factors such as emission characteristics, site layout, buildings, local topography and meteorological conditions.

This can help assess potential odour impacts associated with proposed developments and operational sites.

Odour Risk Assessment and Mitigation

We can assess odour risk using a source-pathway-receptor approach and identify measures that may reduce potential impacts.

Where required, we can provide advice on odour mitigation and prepare Odour Management Plans covering operational controls, monitoring and response procedures.

Our approach is proportionate to the source, sensitivity of the surrounding area and requirements of the planning or permitting process.

NEED ASSISTANCE WITH YOUR PROJECT?

Our expert team of planning specialists, sustainability consultants and Chartered Engineers are here to help.

Get in touch with us today

Question: What is an Odour Assessment?

Answer: An Odour Assessment is a specialist study that evaluates the potential for odour from a development or operation to affect nearby residents and other sensitive receptors. It considers the sources of odour, the effectiveness of any abatement, the local meteorology and the sensitivity of the surrounding area.

Odour assessments are commonly required for planning applications and environmental permits involving commercial kitchens, restaurants and takeaways, wastewater treatment works, anaerobic digestion and composting facilities, waste transfer stations, agricultural operations and industrial processes. They may also be needed where new housing is proposed close to an existing odour source.

 

Question: When is an Odour Assessment required for planning permission?

Answer: Local Planning Authorities typically request an odour assessment where a proposal could generate odour, or where new sensitive uses such as homes, schools or care homes would be introduced near an existing source. Common triggers include:

  • New or extended commercial kitchens and hot food takeaways
  • Residential development near sewage treatment works or waste facilities
  • Waste, recycling, composting and anaerobic digestion facilities
  • Intensive agricultural units
  • Industrial processes with odorous emissions
  • Discharge of planning conditions relating to kitchen extract systems

Environmental Health Officers will usually expect the assessment to follow the Institute of Air Quality Management (IAQM) Guidance on the Assessment of Odour for Planning.

 

Question: What methodology is used in an Odour Assessment?

Answer: The assessment approach is proportionate to the risk. Typical methods include:

  • Qualitative risk assessment using the FIDOL factors (Frequency, Intensity, Duration, Offensiveness and Location)
  • Odour source characterisation and review of abatement measures
  • Sniff testing and odour diary surveys
  • Olfactometry sampling to BS EN 13725
  • Atmospheric dispersion modelling of odour concentrations
  • Comparison against Environment Agency odour benchmark criteria

For kitchen extract systems, the assessment is normally undertaken with reference to the EMAQ+ Control of Odour and Noise from Commercial Kitchen Exhaust Systems guidance.

 

Question: What is odour dispersion modelling?

Answer: Odour dispersion modelling uses software such as ADMS or AERMOD to predict how odour emitted from a source travels and dilutes in the atmosphere. Results are expressed as odour units per cubic metre (ouE/m³) and compared with Environment Agency benchmarks, which range from 1.5 ouE/m³ for highly offensive odours to 6 ouE/m³ for less offensive odours, based on the 98th percentile of hourly means.

Modelling allows the assessment of different stack heights, abatement options and operating scenarios so that the design can be optimised before planning submission or permit application.

 

Question: What is a commercial kitchen extract odour assessment?

Answer: A commercial kitchen extract assessment is a risk-based assessment of a proposed restaurant, takeaway, café or food production facility. It considers the type and volume of cooking, the proximity and sensitivity of neighbours, the extract discharge location and the level of odour control proposed.

The assessment determines the appropriate level of abatement, such as grease filtration, carbon filtration, electrostatic precipitation or UV/ozone treatment, and the required discharge height and velocity. It is commonly used to support planning applications, change of use applications and the discharge of planning conditions.

 

Question: What mitigation measures can reduce odour impact?

Answer: Mitigation depends on the source but may include:

  • Increased stack height and discharge velocity
  • Carbon filtration, biofiltration or thermal oxidation
  • Enclosure of odorous processes and negative pressure buildings
  • Improved process management and housekeeping
  • Restricting operating hours
  • Buffer distances and site layout changes
  • Odour management plans

Where mitigation is secured through planning conditions, the assessment provides the evidence that the measures are appropriate and achievable.

 

Question: What is an Odour Management Plan?

Answer: An Odour Management Plan (OMP) is a document that sets out how an operator will identify, control and monitor odour from a facility. It is commonly required by the Environment Agency as part of an environmental permit and by Local Planning Authorities as a planning condition.

An OMP typically includes a description of odour sources, control measures, monitoring procedures, complaint handling and contingency arrangements for abnormal operations.

 

Question: Why choose Syntegra Group for an Odour Assessment?

Answer: Syntegra Group prepares odour assessments for planning applications, permit applications and planning condition discharge across the UK. Our air quality consultants follow IAQM and Environment Agency guidance and have experience of both simple risk-based kitchen extract assessments and complex dispersion modelling for waste and industrial facilities.

Because we also provide mechanical design and acoustic consultancy, we can design extract and abatement systems that satisfy odour, noise and ventilation requirements together, avoiding conflicting advice and reducing the risk of objections from Environmental Health Officers.